Slave diagnostics

Each slave provides its own diagnostic properties and sub-objects for port errors, redundancy, Distributed Clocks (DC) synchronization and more.

Use with events

Drive exception handling from events (such as SlaveStateChanged, SlaveOffline, DCSyncLost) instead of polling. Reading the slave diagnostic properties directly suits scenarios such as UI display.

Feature overview​

FeatureAccess pathDescription
WKC and health mirrorslave.*Per-slave Working Counter (WKC) / AL / mailbox health diagnostic mirror (WKC and mailbox read as the current value; the AL mirror is a cache sampled while the master is in OP, see AlStatusMirror / AlStatusCode)
Communication diagnosticsslave.Diagnostics.ReadPortErrors()ESC port error counters
Redundancy diagnosticsslave.Diagnostics.*Redundancy activation, primary / redundant line break detection
DC synchronizationslave.Diagnostics.DC.*Sync state, time difference
CategoryPropertyTypeAccessEnable controlDescription
WKC and health mirrorWcContributedWcContributionRead-onlyAlways onContribution state of this slave to the Working Counter; a read returns the real result for the current cycle. NotContributed ≠ master fault — it means this slave is not responding right now (possibly lost, or recovering from a hot-plug exchange)
AlStatusMirrorEcSlaveStatusRead-onlyAlways onLow byte of the AL state of this slave (when the Error bit is set, call .HasFault()). It is a cache sampled while the master is in OP, not the live truth at read time; when not in OP / not sampled it is 0 = unknown
AlStatusCodeEcALStateRead-onlyAlways onAL Status Code of this slave. Only meaningful when AlStatusMirror carries the Error bit; without Error it returns NoError. When not sampled it returns Unknown, and also when the Error bit is set but the mirror's high byte is 0 — unknown is never reported as no error
MailboxHealthEcMailboxHealthRead-onlyAlways onMailbox health of this slave. Degraded means the slave is in OP but its mailbox is half-failed (CoE/SDO may block); reported as measured and never involved in altering WKC
IsFreeRunDemotedboolRead-onlyAlways onWhether this slave was forced down to FreeRun synchronization mode. true only when the configuration requires DC but the run-time fell back to FreeRun — the observation point for the root cause of a half-failure
HealthDegradedCountuintRead-onlyAlways onConsecutive count of mailbox half-failure (approximately seconds). 0 = healthy or not evaluated; a rising value means the half-failure has not recovered, and reaching 3 triggers automatic repair
RecoverMailboxHealth()boolRead-onlyAlways onManually trigger mailbox half-failure repair. Usually you do not need to call it — repair happens automatically after about 3 seconds. Returns false on a communication error instead of throwing
Communication diagnosticsReadPortErrors()EscPortErrors?Read-onlyRead the ESC port error counters. Reads the slave registers in real time; returns null on failure
Redundancy diagnosticsRedundancyActivatedboolRead-onlyAlways onRedundancy protection running = master-level RingMode is Dual or Degraded (criterion: RingMode >= 1); always false in linear / fold-back topologies. This is not a per-slave conclusion, and CRC faults do not trigger it
PrimaryLinkBrokenboolRead-onlyAlways onPrimary line break. A break exists on the path from the primary port (Port0) to this slave. Detects physical breaks only, not CRC faults
SecondaryLinkBrokenboolRead-onlyAlways onRedundant line break. A break exists on the path from the secondary port (Port1) back to this slave. Detects physical breaks only, not CRC faults
DC synchronizationDC.IsInSyncboolRead-onlyAlways onWhether the slave is inside the sync window (the threshold is controlled by master.Diagnostics.SyncWindowThreshold)
DC.SyncTimeDifferenceint?Read-onlyAlways onCurrent time difference from the reference clock (nanoseconds); null when the slave has no DC or the read fails
WcContribution enumeration
ValueNameDescription
0x00NotContributedThis slave is not contributing WKC right now (possibly lost / recovering from a hot-plug exchange)
0x01ContributedThis slave contributes WKC normally (it responds on the bus)
0xFFUnknownNot filled in yet (PDO cycle not running / index out of range) — exposed honestly, never invented
EcMailboxHealth enumeration
ValueNameDescription
0UnknownUnknown / no mailbox / not in OP — mailbox health is meaningless here
1HealthyHealthy — in OP and the mailbox is available
2DegradedDegraded — in OP but the mailbox is half-failed (handler lost / DC demoted with 0x001F)
EscPortErrors struct
CategoryFieldTypeRead/writeDescription
Port errorsRxErrorbyte[]Read-onlyRX error count per port [Port0-3]
InvalidFramebyte[]Read-onlyInvalid frame count per port [Port0-3]
LostLinkbyte[]Read-onlyLink loss count per port [Port0-3]
HasErrorsboolRead-onlyWhether any error is present (read-only derived)
note

The WKC / health mirror, redundancy and DC properties are "always on" (always active); you do not need to enable master.Diagnostics.Enabled. ReadPortErrors() reads the slave in real time; do not call it at a high rate.

WKC and health mirror​

These properties are read directly on slave (not under the slave.Diagnostics sub-object). A read returns the current bus diagnostic result without any refresh call. Together with the master-level master.Diagnostics.WcDeficit you can pinpoint the exact slave when one drops out.

WcContributed (slave WKC contribution)​

public WcContribution WcContributed { get; }

The contribution state of this slave to the Working Counter (WKC).

Observability contract: NotContributed is not a master fault — it means this slave is not responding right now (possibly lost / recovering from a hot-plug exchange); after the repair it returns to Contributed automatically. Before the value is filled in it honestly returns Unknown (0xFF) instead of inventing one.

AlStatusMirror / AlStatusCode​

public EcSlaveStatus AlStatusMirror { get; }
public EcALState AlStatusCode { get; }

AlStatusMirror is the AL state of this slave (low byte = AL State, bit4 = Error bit, test with .HasFault()). When the Error bit is set, AlStatusCode gives the EcALState error code; without Error it returns EcALState.NoError.

This value is a cache refreshed by the master only while it is in OP; it is not the live truth at read time. When the master is not currently in OP (or no sample has been taken yet) the getter returns 0 = not sampled / unknown; only a value other than 0 is a trustworthy sample. Once the master leaves OP the sampler stops and the cache keeps its last sample, so this property no longer claims realtime behaviour.

AlStatusCode extra semantics: Returns Unknown when not sampled, and also when the Error bit is set but the mirror's high byte is 0 — the SDK never reports "unknown" as NoError.

MailboxHealth / IsFreeRunDemoted / HealthDegradedCount / RecoverMailboxHealth()​

Makes the hidden fault "in OP but mailbox half-failed" (CoE/SDO blocking) visible to the upper layer. MailboxHealth == Degraded means the slave is still in OP but its mailbox channel is half-failed. A rising HealthDegradedCount means the half-failure has not recovered (it repairs automatically after about 3 seconds); you can also call RecoverMailboxHealth() to intervene manually. Everything is reported faithfully and never involved in altering WKC.

Example:

foreach (var slave in master.Slaves)
{
// WKC contribution: locate a lost slave
if (slave.WcContributed == WcContribution.NotContributed)
Console.WriteLine($"从站 {slave.SlaveNum} 未贡献 WKC, AL={slave.AlStatusCode}"); // Slave {slave.SlaveNum} not contributing WKC, AL={slave.AlStatusCode}

// mailbox half-failure (in OP but CoE may block)
if (slave.MailboxHealth == EcMailboxHealth.Degraded)
{
Console.WriteLine($"从站 {slave.SlaveNum} 邮箱半失效 {slave.HealthDegradedCount}s" + // Slave {slave.SlaveNum} mailbox partially failed for {slave.HealthDegradedCount}s
(slave.IsFreeRunDemoted ? " (被迫 FreeRun)" : "")); // (forced FreeRun)
if (slave.HealthDegradedCount >= 5)
slave.RecoverMailboxHealth(); // usually already repaired automatically; this is manual intervention
}
}

Communication diagnostics​

ReadPortErrors()​

public EscPortErrors? ReadPortErrors()

Reads the slave ESC port error counters and returns the per-port physical-layer error statistics.

Return value:

  • EscPortErrors? — port error counters; null when the read fails

Example:

foreach (var slave in master.Slaves)
{
var errors = slave.Diagnostics.ReadPortErrors();
if (errors?.HasErrors == true)
{
var e = errors.Value;
Console.WriteLine($"从站 {slave.SlaveNum}: " + // Slave {slave.SlaveNum}:
$"RX错误=[{string.Join(",", e.RxError)}], " + // RX errors=[{string.Join(
$"无效帧=[{string.Join(",", e.InvalidFrame)}], " + // Invalid frames=[{string.Join(
$"链路丢失=[{string.Join(",", e.LostLink)}]"); // Link loss=[{string.Join(
}
}

Redundancy diagnostics​

Access the redundancy state of a slave through slave.Diagnostics. It is meaningful only when redundancy is enabled on the master.

Example:

foreach (var slave in master.Slaves)
{
if (!slave.Diagnostics.RedundancyActivated) continue;

Console.Write($"从站 {slave.SlaveNum}: 冗余激活"); // Slave {slave.SlaveNum}: redundancy active
if (slave.Diagnostics.PrimaryLinkBroken)
Console.Write(", 主线路断路"); // , primary link broken
if (slave.Diagnostics.SecondaryLinkBroken)
Console.Write(", 冗余线路断路"); // , redundancy link broken
Console.WriteLine();
}

DC synchronization​

Access the DC synchronization state of a slave through slave.Diagnostics.DC.

What IsInSync does and does not mean

IsInSync (bool) is the historical boolean contract for whether the slave can be treated as synchronized: it is false when the slave has no DC, when SYNC0 is known to be unarmed, when the read fails, or when the arming result is unknown (failures are visible through ReadFaulted and a Warning log); it returns true when this slave is the reference clock and SYNC0 is armed — 0x092C is by definition N/A for the reference clock itself (no in-sync value is reported for it), and the reference clock cannot be out of step with itself. Both the sync-axis start gate and the clearing of the DC失步 alarm depend on this. That true only means "can be treated as synchronized"; it does not mean a measured deviation exists, nor that the whole network clock has converged. To tell "known not synchronized" apart from "cannot be determined", use the tri-state slave.Diagnostics.DC.SyncState (DcSyncState): both the reference clock itself and a stale sample are Unknown, and you must not read Unknown as out of sync. The two intentionally differ at the reference clock; do not substitute one for the other.

Example:

foreach (var slave in master.Slaves)
{
if (!slave.HasDC) continue;

var dc = slave.Diagnostics.DC;
Console.WriteLine($"从站 {slave.SlaveNum}: " + // Slave {slave.SlaveNum}:
$"时间差={dc.SyncTimeDifference?.ToString() ?? "n/a"}ns, " + // Time diff={dc.SyncTimeDifference?.ToString() ??
$"同步={dc.IsInSync}"); // In sync={dc.IsInSync}
}

Full example​

foreach (var slave in master.Slaves)
{
Console.WriteLine($"--- 从站 {slave.SlaveNum}: {slave.Name} ---"); // --- Slave {slave.SlaveNum}: {slave.Name} ---

// port errors
var errors = slave.Diagnostics.ReadPortErrors();
if (errors?.HasErrors == true)
{
var e = errors.Value;
Console.WriteLine($" 端口错误: RX=[{string.Join(",", e.RxError)}], " + // Port errors: RX=[{string.Join(
$"无效帧=[{string.Join(",", e.InvalidFrame)}], " + // Invalid frames=[{string.Join(
$"链路丢失=[{string.Join(",", e.LostLink)}]"); // Link loss=[{string.Join(
}

// redundancy (meaningful only in redundancy mode)
if (slave.Diagnostics.RedundancyActivated)
{
Console.WriteLine($" 冗余激活: 主线路断={slave.Diagnostics.PrimaryLinkBroken}, " + // Redundancy active: primary link broken={slave.Diagnostics.PrimaryLinkBroken},
$"冗余线路断={slave.Diagnostics.SecondaryLinkBroken}"); // redundancy link broken={slave.Diagnostics.SecondaryLinkBroken}
}

// DC synchronization
if (slave.HasDC)
{
Console.WriteLine($" DC: 时间差={slave.Diagnostics.DC.SyncTimeDifference?.ToString() ?? "n/a"}ns, " + // DC: time diff={slave.Diagnostics.DC.SyncTimeDifference?.ToString() ??
$"同步={slave.Diagnostics.DC.IsInSync}"); // In sync={slave.Diagnostics.DC.IsInSync}
}
}