Skip to main content

CiA 401 — Generic I/O modules

CiA 401 (IEC 61131-9) is the CoE-based device protocol for generic digital / analog I/O devices.

CiA 401 runs on top of CoE (SDO) and is available only when the slave supports CoE.

Accessed directly through slave.cia401(). The child object is created lazily and always returns an instance (never null). CiA 401 runs over CoE, so calling its methods on a slave that is not a CoE / I/O module fails (returns 0 / false); before calling, use slave.supportsCoE() to check whether the slave supports CoE.​

IO properties​

Read and write IO channels directly through the accessors; all channel numbers start at 0.

CategoryPropertyTypeRead/writeDescription
DigitalDI.get(n)booleanread-onlyDigital input channel n
DO.get(n) / DO.set(n, val)booleanread/writeDigital output channel n
AnalogAI.get(n)intread-onlyAnalog input channel n
AO.get(n) / AO.set(n, val)shortread/writeAnalog output channel n

Example:

// the slave.cia401() child object is created lazily and always returns an instance (never null)
CiA401 io = slave.cia401();

// digital IO
boolean sensor = io.DI.get(0);
io.DO.set(0, true);
io.DO.set(1, sensor);

// analog IO
int adc = io.AI.get(0);
io.AO.set(0, (short) 16384);
Real-time control

High-frequency I/O control should use PDO mapping instead of SDO. SDO is suited to parameter configuration and diagnostics.

DI​

public DIAccessor DI;

Digital input accessor. DI.get(channel) reads the high / low level of a single channel by channel number (starting at 0), internally converting to SDO 0x6000 in groups of 8 channels.

Related structures:

public class DIAccessor {
public boolean get(int channel); // read-only, true = high level
}

Example:

boolean ch0 = io.DI.get(0);
boolean ch5 = io.DI.get(5);

DO​

public DOAccessor DO;

Digital output accessor. DO.get(channel) reads back the last written state; DO.set(channel, state) sets the target state (writes SDO 0x6200) without affecting other channels in the same group.

Related structures:

public class DOAccessor {
public boolean get(int channel);
public void set(int channel, boolean state);
}

Example:

io.DO.set(0, true);
io.DO.set(1, io.DI.get(0));
boolean current = io.DO.get(0);

AI​

public AIAccessor AI;

Analog input accessor. AI.get(channel) returns a 16/32-bit signed raw value corresponding to SDO 0x6401 / 0x6402. For an unsigned 32-bit read, use readAI32Unsigned.

Related structures:

public class AIAccessor {
public int get(int channel); // read-only
}

Example:

int adc0 = io.AI.get(0);
double voltage = adc0 * 10.0 / 32768;

AO​

public AOAccessor AO;

Analog output accessor. AO.get(channel) / AO.set(channel, value) read and write a 16-bit signed value (SDO 0x6411). For 32-bit high-precision devices use writeAO32 / readAO32.

Related structures:

public class AOAccessor {
public short get(int channel);
public void set(int channel, short value);
}

Example:

io.AO.set(0, (short) 16384);     // write 50% of full scale
short echo = io.AO.get(0); // read back the current setpoint

Method API​

The accessors call the following methods internally; they can also be used directly.

readDI​

public boolean readDI(int channel)

Reads a digital input. Internally it computes the group number and bit offset automatically in groups of 8 channels.

Parameters:

  • channel — channel number (starting at 0)

writeDO​

public void writeDO(int channel, boolean state)

Sets a digital output without affecting other channels in the same group.

Parameters:

  • channel — channel number (starting at 0)
  • state — target state

readAI​

public int readAI(int channel)

Reads an analog input value. It adapts automatically to 16-bit and 32-bit devices.

Parameters:

  • channel — channel number (starting at 0)

writeAO​

public void writeAO(int channel, short value)

Writes an analog output value.

Parameters:

  • channel — channel number (starting at 0)
  • value — 16-bit output value

readAI32Unsigned​

public long readAI32Unsigned(int channel)

Reads an analog input value (unsigned 32-bit, returned as a long). Suited to high-precision AI devices; data range 0~4294967295.

Parameters:

  • channel — channel number (starting at 0)

Returns:

  • long — unsigned 32-bit analog value

Example:

CiA401 io = slave.cia401();

// signed read (default; large values may become negative)
int aiSigned = io.readAI(0);

// unsigned 32-bit read (high-precision devices)
long aiU32 = io.readAI32Unsigned(0);

Virtual DI writing​

Subindices 01-04 of the virtual digital input object 0x2120 correspond to 4 virtual DI channels. By firmware convention this object must be accessed through the PDO mapping, and an SDO write is rejected by the slave with 0x06020000; writeVirtualDI first attempts SDO and, once rejected, automatically falls back to a PDO write.

writeVirtualDI(int diIndex, boolean state)​

public void writeVirtualDI(int diIndex, boolean state)

Writes one virtual DI channel. After the first SDO rejection, subsequent calls on the same instance go straight to PDO, so the failed attempt is not repeated for every command.

Parameters:

  • diIndex (int) — virtual DI subindex; 1-4 corresponds to 0x2120:01-0x2120:04
  • state (boolean) — target state; true writes 1, false writes 0

Returns: none (void).

Exceptions:

  • IllegalStateException — neither the SDO nor the PDO path can write the value (including the case where the slave has not mapped 0x2120 into the RxPDO); the message includes the slave index and subindex

Example:

CiA401 io = slave.cia401();

// Set virtual DI 1 to 1 and virtual DI 2 to 0
io.writeVirtualDI(1, true);
io.writeVirtualDI(2, false);

WriteVirtualDI(int diIndex, boolean state)​

public void WriteVirtualDI(int diIndex, boolean state)

Cross-language contract name (identical in C# / C++); its semantics, parameters, return value and exceptions are exactly the same as writeVirtualDI(int, boolean), and the call is forwarded to it directly.

Parameters:

  • diIndex (int) — virtual DI subindex (1-4)
  • state (boolean) — target state

Returns: none (void).

Analog input interrupts and limits​

readGlobalInterruptEnable / writeGlobalInterruptEnable​

public int     readGlobalInterruptEnable()
public boolean writeGlobalInterruptEnable(int value)

Reads or sets the analog input global interrupt enable (0x6423).

Parameters:

  • value — enable value (0 = disable, a value other than 0 = enable)

readGlobalInterruptEnableOrNull()​

public Integer readGlobalInterruptEnableOrNull()

Failure-aware read entry point: null = read failure, 0 is a legitimate value (global interrupt disabled). The older readGlobalInterruptEnable() returns 0 on a read failure, indistinguishable from a real 0.

CategoryPropertyTypeRead/writeDescription
Analog inputreadGlobalInterruptEnableOrNull()Integerread-only0x6423 interrupt enable; null = read failure, 0 = real value (disabled)

Example:

Integer en = slave.cia401().readGlobalInterruptEnableOrNull();
if (en == null) {
/* read failure: do not treat it as "interrupt disabled" */
} else if (en == 0) {
/* real 0: the global interrupt really is disabled */
}

readAIUpperLimit / writeAIUpperLimit​

public int     readAIUpperLimit(int channel)
public boolean writeAIUpperLimit(int channel, int value)

Reads or writes the analog input interrupt upper limit (0x6424). An interrupt is triggered when the AI value exceeds the upper limit.

Parameters:

  • channel — channel number (starting at 0)
  • value — upper limit

readAILowerLimit / writeAILowerLimit​

public int     readAILowerLimit(int channel)
public boolean writeAILowerLimit(int channel, int value)

Reads or writes the analog input interrupt lower limit (0x6425). An interrupt is triggered when the AI value falls below the lower limit.

Parameters:

  • channel — channel number (starting at 0)
  • value — lower limit

Example:

CiA401 io = slave.cia401();

// enable the global interrupt
io.writeGlobalInterruptEnable(1);

// set the upper and lower limits of channel 0
io.writeAIUpperLimit(0, 30000);
io.writeAILowerLimit(0, 1000);

// read the current limit configuration
int upper = io.readAIUpperLimit(0);
int lower = io.readAILowerLimit(0);
int enabled = io.readGlobalInterruptEnable();

Bulk IO methods​

Besides per-channel operations, 16/32-bit bulk reads and writes are supported, operating on several channels at once.

readDI16(int group)​

public short readDI16(int group)

Reads 16-bit digital inputs (16 channels).

Parameters:

  • group — group number (subindex, starting at 1)

Returns:

  • short — 16-bit input value, one bit per channel

readDI32(int group)​

public int readDI32(int group)

Reads 32-bit digital inputs (32 channels).

Parameters:

  • group — group number (subindex, starting at 1)

Returns:

  • int — 32-bit input value, one bit per channel

Example:

CiA401 io = slave.cia401();
short di16 = io.readDI16(1); // read channels 0-15
int di32 = io.readDI32(1); // read channels 0-31
boolean ch5 = (di16 & (1 << 5)) != 0; // check channel 5

readDO16 / writeDO16​

public short readDO16(int group)
public void writeDO16(int group, short value)

Reads or writes 16-bit digital outputs (16 channels).

Parameters:

  • group — group number (subindex, starting at 1)
  • value — 16-bit output value

readDO32 / writeDO32​

public int  readDO32(int group)
public void writeDO32(int group, int value)

Reads or writes 32-bit digital outputs (32 channels).

Parameters:

  • group — group number (subindex, starting at 1)
  • value — 32-bit output value

Example:

CiA401 io = slave.cia401();

// 16-bit bulk operation
io.writeDO16(1, (short) 0x00FF); // channels 0-7 output high, 8-15 output low
short do16 = io.readDO16(1); // read back the current value

// 32-bit bulk operation
io.writeDO32(1, 0x0000FFFF); // channels 0-15 output high
int do32 = io.readDO32(1); // read back the current value

readAO32 / writeAO32​

public int  readAO32(int channel)
public void writeAO32(int channel, int value)

Reads or writes 32-bit analog output values. Suited to high-precision analog output devices.

Parameters:

  • channel — channel number (starting at 0)
  • value — 32-bit output value

Example:

CiA401 io = slave.cia401();
io.writeAO32(0, 65536); // write a 32-bit high-precision value
int ao = io.readAO32(0); // read back the current value

Digital input configuration​

setDIPolarity / getDIPolarity​

public void setDIPolarity(int group, byte polarity)
public byte getDIPolarity(int group)

Sets or reads the digital input polarity (0x6002). The input signal logic can be inverted bit by bit.

Parameters:

  • group — group number (subindex, starting at 1)
  • polarity — polarity mask; 1 = invert the corresponding channel

Example:

CiA401 io = slave.cia401();
io.setDIPolarity(1, (byte) 0x0F); // invert the polarity of channels 0-3
byte pol = io.getDIPolarity(1); // read the current polarity configuration

setDIFilter / getDIFilter​

public void setDIFilter(int group, byte filterEnable)
public byte getDIFilter(int group)

Sets or reads the digital input filter enable (0x6003). Used to remove jitter from input signals.

Parameters:

  • group — group number (subindex, starting at 1)
  • filterEnable — filter enable mask

Example:

CiA401 io = slave.cia401();
io.setDIFilter(1, (byte) 10); // set the filter enable
byte flt = io.getDIFilter(1); // read the current filter configuration

getDIPolarityOrNull / getDIFilterOrNull​

public Byte getDIPolarityOrNull(int group)
public Byte getDIFilterOrNull(int group)

Failure-aware read entry points: null = read failure, while a returned 0 is a legitimate value ("polarity not inverted" / "filter all off"). The older getDIPolarity / getDIFilter collapse a read failure to 0 (legacy contract), so their return value alone cannot distinguish "real 0" from "not read".

CategoryPropertyTypeRead/writeDescription
Digital inputgetDIPolarityOrNull(group)Byteread-only0x6002 polarity mask; null = read failure, 0 = real value (no inversion)
getDIFilterOrNull(group)Byteread-only0x6003 filter enable; null = read failure, 0 = real value (all off)

Parameters:

  • group — group number (subindex, starting at 1)

Example:

CiA401 io = slave.cia401();

Byte pol = io.getDIPolarityOrNull(1);
if (pol == null) {
/* read failure: do not treat it as "no channel inverted" */
} else if (pol == 0) {
/* real 0: the device really inverts no channel */
}

Byte flt = io.getDIFilterOrNull(1);
if (flt == null) {
/* read failure: do not treat it as "filter all off" */
}

Error status reading​

getDOErrorMode / getDOErrorValue​

public ErrorMode getDOErrorMode(int group)
public byte getDOErrorValue(int group)

Reads the current configuration of the digital output error mode and error safe value.

Parameters:

  • group — group number (starting at 0)

Example:

CiA401 io = slave.cia401();
CiA401.ErrorMode mode = io.getDOErrorMode(0);
byte safeVal = io.getDOErrorValue(0);
System.out.printf("错误模式: %s, 安全值: 0x%02X%n", mode, safeVal); // Error mode: %s, safe value: 0x%02X%n

Error handling​

dOErrorMode​

public void dOErrorMode(int group, ErrorMode mode)

Sets the digital output error mode. It determines how the outputs respond when EtherCAT communication is lost.

Parameters:

  • group — group number (starting at 0; one group per 8 channels: group 0 = channels 0-7, group 1 = channels 8-15)
  • mode — error mode

Related structures:

public enum ErrorMode {
HOLD((byte) 0), // hold the current output value
SAFE_VALUE((byte) 1); // switch to the preset safe value
}

dOErrorValue​

public void dOErrorValue(int group, byte value)

Sets the safe value for the digital outputs when communication is lost. Effective only in SAFE_VALUE mode.

Parameters:

  • group — group number (starting at 0)
  • value — safe output value (8-bit, one bit per channel)

aOErrorMode​

public void aOErrorMode(int channel, ErrorMode mode)

Sets the analog output error mode.

Parameters:

  • channel — channel number (starting at 0)
  • mode — error mode

aOErrorValue​

public void aOErrorValue(int channel, short value)

Sets the safe value for the analog outputs when communication is lost. Effective only in SAFE_VALUE mode.

Parameters:

  • channel — channel number (starting at 0)
  • value — 16-bit safe output value

Example:

io.dOErrorMode(0, CiA401.ErrorMode.SAFE_VALUE);
io.dOErrorValue(0, (byte) 0x00);

io.aOErrorMode(0, CiA401.ErrorMode.SAFE_VALUE);
io.aOErrorValue(0, (short) 0);

Standard object index constants​

Can be used with slave.coe().SDORead / SDOWrite for direct access:

ConstantValueDescription
OD_DI0x6000Digital inputs
OD_DI_16BIT0x600116-bit digital inputs
OD_DI_POLARITY0x6002Digital input polarity
OD_DI_FILTER0x6003Digital input filter enable
OD_DI_INTERRUPT0x6005Digital input interrupt trigger
OD_DI_INTERRUPT_EDGE0x6006Digital input interrupt edge
OD_DI_32BIT0x602032-bit digital inputs
OD_DO0x6200Digital outputs
OD_DO_16BIT0x620116-bit digital outputs
OD_DO_POLARITY0x6202Digital output polarity
OD_DO_ERROR_MODE0x6206Digital output error mode
OD_DO_ERROR_VALUE0x6207Digital output error value
OD_DO_32BIT0x622032-bit digital outputs
OD_AI0x6400Analog inputs
OD_AI_SI_UNIT0x6420Analog input range
OD_AI_GLOBAL_INTERRUPT0x6423Analog input global interrupt enable
OD_AI_UPPER_LIMIT0x6424Analog input interrupt upper limit
OD_AI_LOWER_LIMIT0x6425Analog input interrupt lower limit
OD_AO0x6411Analog outputs
OD_AO_32BIT0x641232-bit analog outputs
OD_AO_SI_UNIT0x6430Analog output range
OD_AO_ERROR_MODE0x6443Analog output error mode
OD_AO_ERROR_VALUE0x6444Analog output error value

Complete example​

// the slave.cia401() child object is created lazily and always returns an instance (never null)
CiA401 io = slave.cia401();

// digital IO
boolean sensor = io.DI.get(0);
boolean limit = io.DI.get(5);

io.DO.set(0, true);
io.DO.set(1, sensor);

// analog IO
int adc = io.AI.get(0);
double temp = adc * 0.1;
io.AO.set(0, (short) (temp > 50 ? 0 : 16384));

// safety configuration
io.dOErrorMode(0, CiA401.ErrorMode.SAFE_VALUE);
io.dOErrorValue(0, (byte) 0x00);