Skip to main content

Slave properties and methods

Accessed through master[n] or master.slave(n) (1-based index).​

Properties​

CategoryPropertyTypeRead/writeDescription
Basic identificationslave_numintread-onlySlave index (1-based)
namestrread-onlySlave group name (group_name, the ESI GroupType name)
drive_namestrread-onlyDevice name (the ESI device name when ESI matching succeeds, otherwise the SII EEPROM name)
Device informationvendor_idintread-onlyManufacturer ID (read from the SII EEPROM)
vendor_namestrread-onlyManufacturer name. The current version always returns an empty string (the read interface always writes empty), so it cannot be used to determine the vendor name
product_idintread-onlyProduct ID
rev_idintread-onlyRevision number
serial_numberintread-onlySerial number (native runtime identity snapshot); 0 has three meanings — not read / real value 0 / read failed; use slave.try_get_serial_number() for the real value (see SII identity area and true serial number)
has_mdpboolread-onlyWhether the modular device profile is supported (ETG.5001)
block_lrwboolread-onlyLRW logical read/write blocking flag
device_emulationboolread-onlyWhether this is a Device Emulation device
device_emulation_flagboolread-onlyAlias of device_emulation (the same test)
Addressconfig_addrintread-onlyPhysical configuration address
alias_addressintread-onlyAlias address
StatusstateEcStateread-onlyThe slave's basic state (the low 4 bits of AL Status); it drops the Error bit: 0x14/0x18 are shown as SAFE_OP/OP. To judge errors use has_error / state_raw / status
state_rawintread-onlyRaw byte 0-255 of AL Status (0x0130), with bit4 (Error) preserved; a read failure returns the 0 sentinel
state_live_readLiveReadread-onlyLive state read (forces one real read) plus four-state trust; value is the raw AL Status byte (low 4 bits = base state, bit4 = Error), usable as the current state only when is_valid. Use state / state_raw for the cached view
state_liveOptional[EcState]read-onlyConvenience entry point for state_live_read: gives a value only when VALID, otherwise None. None = there is no trustworthy current state, which is not the same thing as EcState.NONE (value 0)
state_raw_liveOptional[int]read-onlyRaw live state byte 0-255 (including the bit4 Error bit); None when untrusted
has_errorboolread-onlystate_raw & 0x10: whether the slave is currently in an error state
statusEcStateread-onlyFull state view (same semantics as C# (EcState)raw): 0x14/0x18 are both representable; base_state takes the low 4 bits, format() produces SafeOp+Error / OP+Error
error_codeEcALStateread-onlyError code (real read: the full 16-bit ALstatuscode in the slave structure; reads the polled cache while in OP and refreshes with one live frame otherwise; not the mirror high byte of diagnostics.al_status_mirror.al_status_code; al_status_code is an alias of it; codes outside the table return an instance carrying the original code, not folded to UNKNOWN)
al_status_code_rawintread-onlyLossless raw AL Status Code 0-65535; a read failure returns 0xFFFF (the EcALState.UNKNOWN sentinel)
al_status_code_live_readLiveReadread-onlyLive AL Status Code (lossless 16-bit) plus four-state trust. When the slave is lost / not responding native returns 0; this entry point judges it STALE; 0 is not "no error"
al_status_code_liveOptional[EcALState]read-onlyGives a value only when VALID, otherwise None (not NO_ERROR); out-of-table codes are returned carrying the raw code
al_status_code_raw_liveOptional[int]read-onlyLive AL code lossless raw value 0-65535; None when untrusted (never returns 0 to pass as "no error")
is_lostOptional[bool]read-onlyWhether the slave has been judged lost (three states: True = judged lost / False = not judged lost / None = read failure; None does not mean online)
livenessSlaveLivenessStateread-onlyLiveness three-state: ALIVE = confirmed alive / LOST = confirmed offline / UNKNOWN = insufficient evidence. is_lost only answers "is it confirmed lost"; use this property to tell "insufficient evidence"
offline_reasonSlaveOfflineReasonread-onlyOffline reason classification: RealOffline = truly offline / Unreachable = not confirmed by the server — the server/probe did not see it, but the process data proves it is still contributing (not a confirmed offline) / Unknown = insufficient evidence
has_entered_operationalboolread-onlyWhether it has ever successfully entered OP during this run (event-latched; falls back to the current-cycle state when the event surface is not ready)
dropped_from_operationalboolread-onlyWhether it "entered OP but is not in OP now" (dropped out of OP at runtime)
out_of_op_duration_msOptional[int]read-onlyMonotonic duration the slave has continuously been out of OP (ms); None = no provable start of the out-of-OP period. System clock changes do not affect this value
out_of_op_durationOptional[datetime.timedelta]read-onlyHow long it has continuously been out of OP; None has the same meaning as above
out_of_op_since_utcOptional[datetime]read-onlyStart of the out-of-OP period (UTC, derived from "current UTC - monotonic duration"); None has the same meaning as above
input_data_validityPdoInputValidityread-onlyFour-state validity of the input process data: VALID = this cycle's data is valid; DEGRADED = this cycle has no full evidence (the group's inputs are incomplete for this cycle; on a single dropped frame / WKC=0 the data is the previous valid frame (last-good); when some slaves are missing, the input bytes of the absent slave and everything downstream may be the process-image initial values established at startup, do not treat it as definitely trustworthy); STALE = cannot be used as the current value; UNKNOWN = no evidence. Use this property to decide "can this frame of data be used"; use is_lost to decide "has the slave been confirmed offline"
needs_reconfigboolread-onlyWhether startup parameters and configuration need to be replayed after hot-plug
Topologylink_countintread-onlyMeasured link count for the current sample: 1..4 = measured number of connections, -1 = unknown or invalid argument (a 0 placeholder from an unread DLSTAT also counts as unknown); unknown does not mean offline
topology_typeOptional[int]read-onlyConfiguration-time topology structure classification snapshot: 0 = NoLink / 1 = EndPoint / 2 = Line / 3 = Fork / 4 = Cross; None = unavailable (None ≠ 0, 0 is a valid "no link"); unplugging a cable does not change it, and it is not a per-sample measurement
parent_indexintread-onlyParent slave index (1-based), 0 = the parent node is the master; a read failure or an invalid index returns 0xFFFF
parent_stationintread-onlyParent slave index (1-based; the name is historical, it is actually an index, not a station address; 0 = the parent node is the master, a read failure or an invalid index returns 0xFFFF)
parent_portintread-onlyParent port number: 0..3, -1 = unknown or invalid argument; unknown does not mean P0
p1_foldback_onlyintread-onlyP1 fold-back reachability: 1 = reachable only through the fold-back window, 0 = not a branch slave or not calibrated, -1 = unavailable (invalid master / slave index or read failure)
entry_portintread-onlyEntry port number
active_portsintread-onlyActive port bitmask
physical_typeintread-onlyPhysical port type
child_countintread-onlyNumber of child modules
PDO dataibits / obitsintread-onlyInput/output data bit count
ibytes / obytesintread-onlyInput/output data byte count
ioffset / ooffsetintread-onlyInput/output offset in the process image
istartbit / ostartbitintread-onlyInput/output start bit
ESI/configurationhas_esiboolread-onlyWhether slave identity information was read. The current version only checks vendor_id != 0; it does not mean an ESI file was actually loaded and parsed
esi_versionstrread-onlyESI version. The current version always returns an empty string (the SII EEPROM cannot provide this field directly)
EEPROMeep_8byte_addressingboolread-onlyEEPROM addressing mode (True = 8-byte, False = 4-byte)
eep_pdiintread-onlyPhysical device interface (PDI) type
ebus_currentintread-onlyE-bus current consumption (mA)
Mailboxmbx_protointread-onlySupported mailbox protocol bitmask (ECT_MBXPROT_*: AoE=0x01, EoE=0x02, CoE=0x04, FoE=0x08, SoE=0x10, VoE=0x20)
mbx_lengthintread-onlyMailbox send buffer size
mbx_read_lengthintread-onlyMailbox receive buffer size
mbx_read_offset / mbx_write_offsetintread-onlyMailbox read/write offset
mbx_countintread-onlyMailbox protocol counter
Protocol detailscoe_detailsintread-onlyCoE protocol feature flags (EcCoEDetails bitmask)
eoe_detailsintread-onlyEoE protocol feature flags (EcEoEDetails bitmask)
foe_detailsintread-onlyFoE protocol details (from the SII EEPROM)
soe_detailsintread-onlySoE protocol details (from the SII EEPROM)
FMMUfmmu0_functionintread-onlyFMMU0 function type: 0 = unused, 1 = output, 2 = input, 3 = SM status (taken from the Function byte of the SII FMMU section; it is a type code, not a bitmask)
fmmu1_functionintread-onlyFMMU1 function type
fmmu2_functionintread-onlyFMMU2 function type
fmmu3_functionintread-onlyFMMU3 function type
DChas_dcOptional[bool]read-onlyWhether DC is supported: True / False is an ESC hardware bit conclusion; a read failure returns None (unknown)
dc_activeintread-onlyCommitted 0x0980 AssignActivate value (0 = not enabled, non-0 = DC-active). Non-0 does not mean armed or synchronized: check sync0_armed for arming and sync_window.in_sync for synchronization
dc_cycle0intread-onlySYNC0 cycle (ns)
dc_cycle1intread-onlySYNC1 cycle (ns)
dc_shiftintread-onlyPhase shift (ns)
dc_nextintread-onlyIndex of the next slave in the DC chain
dc_previousintread-onlyIndex of the previous slave in the DC chain
dc_receive_time_aintread-onlyPort A receive time (ns)
dc_receive_time_bintread-onlyPort B receive time (ns)
dc_receive_time_cintread-onlyPort C receive time (ns)
dc_receive_time_dintread-onlyPort D receive time (ns)
propagation_delayintread-onlyPropagation delay of the frame from the master to this slave (ns)
pdelayintread-onlyPropagation delay (ns), an alias of propagation_delay
Topology extensionschildrenList[Slave]read-onlyList of child slaves (used with child_count to navigate the topology tree)
supports_frame_repeatboolread/writeWhether frame repeat is supported (ETG.1500 5.4.3)
Redundancyredundancy_activatedboolread-onlyRedundancy activated (master ring mode is DUAL or DEGRADED) = the same master-level criterion master.redundancy_ring_mode >= RingMode.DUAL; always False for linear / end fold-back topologies, not an independent per-slave conclusion
primary_link_brokenboolread-onlyWhether the primary link is broken
secondary_link_brokenboolread-onlyWhether the redundant link is broken
Runtime diagnosticsemcy_countintread-onlyNumber of EMCY emergency messages
emcy_historyList[EmergencyMessage]read-onlyEMCY history (up to the most recent 256 entries, in chronological order oldest → newest; each entry is a read-only EmergencyMessage snapshot accessed through properties)
link_qualityintread-onlyLink quality (0-100%, -1 = unknown)
sync_window_statusdict | Noneread-onlySync window status (keys diff_ns / max_diff_ns / min_diff_ns / in_sync / out_of_sync_count); a read failure returns None
Configurationgroupintread/writeSlave group number (0-7; 0 = unassigned, automatically placed in group 1 before mapping; 1-7 are valid PDO groups; must be set before SAFE_OP)
is_optionalboolread/writeOptional slave flag: when absent it does not affect the WKC check and does not raise a group offline alarm (must be set before OP)
op_onlyboolread-onlyWhether the OpOnly flag is set
op_only_flagboolread-onlyAlias of op_only (the same test)
esm_timeoutsOptional[SlaveEsmTimeouts]read/writeESM state transition timeout configuration (ms); None on a read failure, throws RuntimeError on a write failure
EcTopologyType / EcPortType enumeration values
class EcTopologyType(IntEnum):
NO_LINK = 0 # No link
END_POINT = 1 # Endpoint
LINE = 2 # Intermediate node (linear topology)
FORK = 3 # Fork point
CROSS = 4 # Cross point

class EcPortType(IntEnum):
NOT_USED = 0 # Not used
MII = 1 # MII
EBUS = 2 # EBUS
EBUS_ENHANCED = 3 # EBUS enhanced
MailboxType constants

Type codes in the mailbox header (not the mbx_proto bitmask; mbx_proto uses the ECT_MBXPROT_* bits).

class MailboxType(IntEnum):
ERROR_MAILBOX = 0x00 # Error mailbox
ADS_OVER_ETHERCAT = 0x01 # AoE
ETHERNET_OVER_ETHERCAT = 0x02 # EoE
CANOPEN_OVER_ETHERCAT = 0x03 # CoE
FILE_OVER_ETHERCAT = 0x04 # FoE
SERVO_OVER_ETHERCAT = 0x05 # SoE
VENDOR_OVER_ETHERCAT = 0x0F # VoE
EcCoEDetails constants
class EcCoEDetails(IntFlag):
NONE = 0x00
SDO = 0x01 # SDO supported
SDO_INFO = 0x02 # SDO Info supported
PDO_ASSIGN = 0x04 # PDO Assign supported
PDO_CONFIG = 0x08 # PDO Config supported
STARTUP = 0x10 # Startup supported
COMPLETE_ACCESS = 0x20 # Complete Access supported
EcEoEDetails constants
class EcEoEDetails(IntFlag):
NONE = 0x00
SEND_FRAME = 0x01 # Frame sending supported
RECEIVE_FRAME = 0x02 # Frame receiving supported
SET_IP_PARAM = 0x04 # Setting IP parameters supported
GET_IP_PARAM = 0x08 # Getting IP parameters supported
SlaveEsmTimeouts fields

ESM state transition timeout configuration; every entry is in milliseconds.

FieldTypeDescription
ipintInit → PreOp
psintPreOp → SafeOp
sointSafeOp → OP
osintOP → SafeOp
spintSafeOp → PreOp
piintPreOp → Init
biintAny state → Boot
ibintBoot → Init
Python-specific syntax sugar

The identity tuple (vendor / product / revision / serial) is returned as a dict by the main SDK and cannot be hashed or unpacked. Wrapping it in the SlaveIdentityKey frozen dataclass makes it usable as a dict key / set element plus tuple unpacking. It is provided by the syntax-sugar subpackage, and you must first import darra_ethercat.sugar in your code (or from darra_ethercat.sugar import SlaveIdentityKey): vendor, product, rev, serial = SlaveIdentityKey.from_slave(slave).

Sub-objects​

CategoryPropertyTypeRead/writeDescription
Data and eventspdoSlavePdoread-onlyPDO data accessor
eventsSlaveEventsread-onlySlave-level events
diagnosticsSlaveDiagnosticsread-onlyDiagnostics accessor
startupStartupParameterListread-onlyStartup parameter list
Protocol instancescoeCoEread-onlyCANopen over EtherCAT (created lazily; use coe.is_supported to determine support)
soeSoEread-onlyServo over EtherCAT (created lazily; check support with soe.is_supported)
foeFoEread-onlyFile over EtherCAT (created lazily; check support with foe.is_supported)
eoeEoEread-onlyEthernet over EtherCAT (created lazily; check support with eoe.is_supported)
aoeAoEread-onlyADS over EtherCAT (created lazily; check support with aoe.is_supported)
voeVoEread-onlyVendor over EtherCAT (created lazily; check support with voe.is_supported)
fsoeFSoEread-onlyFunctional Safety over EtherCAT (created lazily; check support with fsoe.is_supported)
cia402CiA402read-onlyCiA 402 drive (created lazily)
cia401CiA401read-onlyCiA 401 I/O module (created lazily)
mdpMdpDiscovery | Noneread-onlyMDP modular device; None when the slave does not support MDP
dc_configDcConfigread-onlyDC synchronization configuration and diagnostics
Protocol capabilities are tri-state (differs per protocol)

is_supported returns Optional[bool], but not every protocol ever returns False:

  • coe / eoe / foe: True = supported, False = confirmed unsupported by a real SII read, None = unknown.
  • aoe / voe / soe / fsoe: this chain only produces True / None (None = no positive evidence or a read failure; it is not folded into "confirmed unsupported").

On slave.eoe (the base EoE) it is a property; on EoEAdvanced it is a method that takes an explicit mailbox protocol bit field, and it also returns tri-state (EoEAdvanced currently has no public entry point that returns an instance, see EoE). Do not use if x.is_supported: to treat "unknown" as "unsupported" or "supported"; when you need to distinguish, test with is True / is False / is None separately.

Enum descriptions​

How to get an enum description depends on the enum:

  • EcState: use .name for the symbolic name (such as "OP") and .format() for a readable string (such as "SafeOp+Error").
  • EcALState / SDOError / EcPortType / EcTopologyType and so on: use .describe() for the Chinese description.
  • ModeCiA402 / StateCiA402 / RedundancyState: use .description for the Chinese description.
state = slave.state
desc = state.name # "OP"

# CiA402 is accessed through slave.cia402 (created lazily, always returns an instance)
cia = master[1].cia402
state = cia.state_drive # Drive state (StateCiA402)

Hardware information queries​

FMMU / SyncManager reads and configuration are performed item by item:

  • FMMU function type: the fmmu0_function to fmmu3_function properties (0 = unused, 1 = output, 2 = input, 3 = SM status)
  • FMMU mapping write: configure_fmmu(fmmu_index, logical_addr, length, logical_start_bit=0, logical_end_bit=7, physical_addr=0, physical_start_bit=0, fmmu_type=0, enable=True) — returns bool
  • SyncManager configuration: configure_sync_manager(sm_index, start_addr, length, sm_type=0, enable=True) — sm_type is 0 = unused / 1 = mailbox output / 2 = mailbox input / 3 = process data output / 4 = process data input; returns bool
  • Output SM enable/disable: enable_output_sync_manager() / disable_output_sync_manager() — return bool
  • Type constants: darra_ethercat.data.types / EcFmmuType in EcSyncManagerType
note

There is no bulk array query member on the Python side (no interface exists that returns all FMMU / SyncManager configuration or type arrays at once; calling one raises AttributeError). For register-level detail of each SM, read it directly with read_register, or walk the SII categories through slave.sii.

Diagnostics​

tip

Slave diagnostics (communication error rate, redundancy state, DC synchronization) are accessed through slave.diagnostics.

PdoInputValidity — input data validity​

slave.input_data_validity answers "can this frame of input data be used as the current value", which is a different fact from "has the slave been confirmed offline" (slave.is_lost).

ValueWhat you seeRecommended use
VALIDThis cycle's PDO exchange was complete; the input image is the current valueUse normally
DEGRADEDThis cycle has no full evidence: the group's inputs are incomplete for this cycle. On a single dropped frame / WKC=0 the data is the previous valid frame (last-good); when some slaves are missing, the input bytes of the absent slave and everything downstream may be the process-image initial values established at startup, not the last valid valueDo not treat this as "the data is definitely trustworthy": either wait for recovery, or cross-check is_lost / offline_reason / input_data_validity to see which slaves are untrustworthy. It turns STALE only after N full cycles without recovery (N is computed from the group cycle and the slave watchdog)
STALEThe input image cannot be used as the current value (WKC short / no frame this cycle / slave lost / exchange stalled)Do not use as a live value; take the safe fallback
UNKNOWNNo evidence (no input PDO / group expectation not established / never exchanged / read failed)Unknown is not valid; treat it as unavailable

A read failure / out-of-range index / an older runtime without this capability returns UNKNOWN (fail-closed).

Note: the native-side comment still says "three-state / degradation pending", which is stale text awaiting sync in the native domain; the public SDK contract is the four states in this section.

diagnostics.stale_input_count counts only slaves confirmed STALE; it does not count while DEGRADED applies.

Diagnostics mirror (thin read)​

The per-slave diagnostics properties live on slave.diagnostics (Python convention: use properties, not get_xxx() methods), and most of them are thin reads of the per-slave diagnostics cache: each access reads the live state directly, sends and receives no frames (zero frames), performs no second-level caching, and what you read is the bus reality at that moment, with no manual refresh needed. The exception is al_status_mirror: it is a cache sampled while the master is in OP, not the live truth at read time (see below). When communication fails they honestly return UNKNOWN / raw=0 instead of making something up.

  • diagnostics.wc_contributed (WcContribution) — this slave's contribution state to the working counter (WKC) in the current cycle
  • diagnostics.al_status_mirror (SlaveAlStatusMirror) — AL status mirror (contains al_state / has_error / al_status_code; al_status_code is the mirror's high byte (the low 8 bits of the AL Status Code, present only when the Error bit is set and the code is non-0; codes ≥0x0100 are truncated, so it only covers 0-255); for the full 16-bit code read the ESC register with read_register(0x0134, 2)). This value is a cache refreshed by the master only while it is in OP; it is not the live truth at read time. When the master is not currently in OP (or no sample has been taken yet) the getter returns 0 = not sampled / unknown; only a non-0 value is a trustworthy sample. Once the master leaves OP the sampler stops and the cache keeps its last sample, so this property no longer claims realtime behaviour.
  • diagnostics.mailbox_health (EcMailboxHealth) — mailbox health of this slave (UNKNOWN/HEALTHY/DEGRADED)
  • diagnostics.is_free_run_demoted (bool) — whether this slave was forced to fall back from DC to FreeRun
  • diagnostics.health_degraded_count (int | None) — consecutive accumulated count of mailbox half-failures on this slave (approximately seconds); a read failure returns None
  • diagnostics.recover_mailbox_health() (bool) — manually trigger mailbox half-failure repair (usually repaired automatically)
WcContribution enumeration values (WKC contribution state)
class WcContribution(IntEnum):
NOT_CONTRIBUTED = 0x00 # This slave is not contributing WKC right now (slave loss / no response)
CONTRIBUTED = 0x01 # This slave contributes WKC normally (responds on the bus)
UNKNOWN = 0xFF # Not filled in / not mapped by the SDK — honestly unknown, not treated as no contribution
EcMailboxHealth enumeration values (mailbox health)
class EcMailboxHealth(IntEnum):
UNKNOWN = 0 # No mailbox / not in OP — mailbox health is meaningless here
HEALTHY = 1 # In OP and the mailbox is usable
DEGRADED = 2 # In OP but the mailbox half-fails (CoE/SDO may block)

WKC contribution semantics​

slave.diagnostics.wc_contributed reflects whether this slave is really responding right now:

  • CONTRIBUTED — this slave contributes its working counter (WKC) normally, meaning that when the aggregate WKC is complete (actual == expected, that is, the master-level diagnostics_info.wc_deficit == 0), the per-slave byte-by-byte comparison is "full" for every slave.
  • NOT_CONTRIBUTED — this slave is not contributing WKC right now (suspected slave loss / hot-plug recovery in progress). This is not a master fault; once the slave is repaired the state naturally returns to CONTRIBUTED.
  • UNKNOWN — not filled in / not mapped by the SDK, exposed honestly, never made up as "contributed".
Reliability invariant

This property only "reflects bus reality as it is" and takes part in no WKC tampering / accommodation logic. The per-slave contribution bit is the per-station breakdown of the aggregate WKC deficit (expected - actual): a deficit greater than 0 means some slave is not contributing right now, which should raise an alarm and diagnostics; do not lower expected and do not stop OP.

Example:

from darra_ethercat.data.types import WcContribution, EcMailboxHealth

for slave in master:
if slave.diagnostics.wc_contributed == WcContribution.NOT_CONTRIBUTED:
al = slave.diagnostics.al_status_mirror
print(f"从站 {slave.slave_num} 此刻未贡献 WKC(疑似掉站),AL Code=0x{al.al_status_code:04X}") # Slave {slave.slave_num} is not contributing WKC at the moment (suspected slave loss), AL Code=0x{al.al_status_code:04X}
if slave.diagnostics.mailbox_health == EcMailboxHealth.DEGRADED:
print(f"从站 {slave.slave_num} 在 OP 但邮箱半失效, 已持续 {slave.diagnostics.health_degraded_count}s") # Slave {slave.slave_num} is in OP but the mailbox is partially failing, for {slave.diagnostics.health_degraded_count}s so far

EMCY emergencies​

Per-slave EMCY records live on Slave (not on slave.coe), and their only source is the underlying ring buffer:

  • emcy_count (int) — number of emergency messages
  • emcy_history (List[EmergencyMessage]) — emergency history (up to the most recent 256 entries, in chronological order oldest → newest). Each entry is a read-only EmergencyMessage snapshot accessed through properties: rec.error_code / rec.error_register / rec.data / rec.slave_index / rec.timestamp_ms
  • clear_emcy() — clear the emergency history
for rec in slave.emcy_history:
print(f"从站 {rec.slave_index} EMCY 0x{rec.error_code:04X} " # Slave {rec.slave_index} EMCY 0x{rec.error_code:04X}
f"reg=0x{rec.error_register:02X} t={rec.timestamp_ms}ms")
slave.clear_emcy()
  • link_quality (int) — link quality (0-100%, -1 = unknown)
  • read_port_error_counters() (dict | None) — port error counters; returns {'rx_error': [4], 'invalid_frame': [4], 'lost_link': [4]} (one entry per port); returns None on failure
  • reset_port_error_counters() (bool) — zero the port error counters
  • sync_window_status (dict | None) — sync window status (keys diff_ns / max_diff_ns / min_diff_ns / in_sync / out_of_sync_count); returns None on failure
  • reset_sync_stats() — reset the sync window statistics

Port error counter exception: read_port_error_counters() really reads ESC registers 0x0300-0x0313 (3 FPRD operations), so it sends frames on the bus; do not put it in a high-frequency loop. It returns None on a read failure. The remaining diagnostic items (WKC contribution / AL status mirror / mailbox health / link quality / sync window / EMCY) are all thin reads of the per-slave diagnostics cache and send no frames.

port_error_stats()​

def port_error_stats(self)

Get a read-only pointer to the underlying port error statistics structure of this slave.

Returns:

  • int — structure address (pointing at the underlying static cache); returns None when the pointer is empty
  • The structure holds 4 ports × 4 counter groups: receive error / invalid frame / lost link / forwarded receive error, 4 bytes each

Notes:

  • What you get back is a pointer, not a dict, so copy the data out according to the structure you declared yourself; the same static cache is overwritten by later reads, so you must copy it immediately and must not keep the address until the next sample.
  • It sends no bus frames; it reads a statistics cache that the underlying layer already maintains.
For everyday diagnostics use read_port_error_counters()

port_error_stats() only gives you an address, which suits scenarios where you already hold the matching structure definition and need the forwarded receive error counters. In ordinary scenarios use read_port_error_counters(): it returns {'rx_error': [4], 'invalid_frame': [4], 'lost_link': [4]} directly and returns None on failure.

Example:

ptr = slave.port_error_stats()
if ptr:
print(f"端口统计结构地址: 0x{ptr:X}") # Port statistics struct address: 0x{ptr:X}

ESI methods​

set_esi_file(esi_file_name)​

def set_esi_file(esi_file_name: str) -> bool

Set the ESI file used by the slave.

Returns:

  • bool — whether the call succeeded
config_by_esi / configure_from_esi are not implemented

slave.config_by_esi() and slave.configure_from_esi() always raise NotImplementedError (the old implementation returned fake success; it now raises explicitly). ESI parsing is done inside the underlying library, and the Python public surface does not provide a slave.esi / EsiLoader query entry point; just hand the ESI path to master.set_eni() / master.set_esi_file() / master.set_esi_files(). Automatic configuration of SM physical parameters goes through master.auto_configure_sm(slave_index).

Process data watchdog​

set_watchdog(timeout_ms)​

def set_watchdog(timeout_ms: int) -> bool

Set the slave process data watchdog timeout. The slave raises a watchdog error (ALStatusCode 0x001B, SYNC_MANAGER_WATCHDOG) when it receives no process data frame within the timeout.

Parameters:

  • timeout_ms (int) — timeout in milliseconds; 0 = disabled; the pre-checked range is 0..6553 (the watchdog counter register is u16 × 0.1ms), and anything out of range throws immediately, with no truncation and no clamping

Return value and exceptions (three states reported honestly):

  • True — the value actually written equals the requested value and the register write succeeded
  • Throws WatchdogTimeoutError (a ValueError subclass) with actual_ms set to None — the request exceeds the 6553ms register limit, so it was rejected and no register was written; the current value stays unchanged
  • Throws WatchdogTimeoutError with actual_ms holding a value — the value was raised to the safe minimum and written (5000ms for branch slaves / 400ms for PDO slaves on a ring; required by the topology protocol, because writing it as requested would cause false slave loss). The register now holds actual_ms, not the requested value. If the actual value cannot be read after raising it, actual_ms is None and the exception message explains why
  • False — the register write failed / the index is invalid (the underlying layer gives no specific error code); the value is unchanged

Example:

from darra_ethercat import WatchdogTimeoutError

try:
ok = slave.set_watchdog(100)
print("已按请求写入" if ok else "寄存器写失败 / 索引无效") # Written as requested / register write failed or index invalid
except WatchdogTimeoutError as e:
if e.actual_ms is None:
print(f"请求被拒绝,未写入:{e}") # Request rejected, nothing written: {e}
else:
print(f"被安全下限抬升并写入,实际 {e.actual_ms} ms") # Raised to the safety lower limit and written; actual value {e.actual_ms} ms
note

Call this in SafeOp or OP state.

set_pdi_watchdog(timeout_ms)​

def set_pdi_watchdog(timeout_ms: int) -> bool

Set the slave PDI watchdog timeout. The PDI watchdog monitors whether the slave's local application (microcontroller firmware) is running normally.

Parameters:

  • timeout_ms (int) — timeout in milliseconds; 0 = disabled; the pre-checked range is 0..6553; anything out of range throws immediately

Return value and exceptions (same semantics as set_watchdog):

  • True — written as requested
  • Throws WatchdogTimeoutError with actual_ms set to None — above the 6553ms register limit; rejected and not written
  • False — the register write failed / the index is invalid

PDI has no safe minimum, so the "raised and then written" branch never occurs (actual_ms is None only on rejection).

Example:

slave.set_pdi_watchdog(100)  # 100ms timeout
slave.set_pdi_watchdog(0) # Disable the PDI watchdog

watchdog_config​

@property
def watchdog_config(self) -> Optional[dict]

Read the slave's current watchdog configuration. A return value of None means the read failed.

Returns:

  • Optional[dict] — watchdog configuration dictionary with the following keys:
    • divider (int) — watchdog divider
    • pdi_timeout (int) — PDI watchdog timeout value (in divider units)
    • pd_timeout (int) — process data watchdog timeout value (in divider units)

Example:

config = slave.watchdog_config
if config is not None:
print(f"PD超时: {config['pd_timeout']} × {config['divider'] * 0.04}µs") # PD timeout: {config['pd_timeout']} × {config['divider'] * 0.04}µs

watchdog_status​

@property
def watchdog_status(self) -> Optional[dict]

Read the slave watchdog runtime status. A return value of None means the whole call failed (read failure).

On a successful call, the dictionary determines validity valid_maskfield by field** from the returned valid bit set **; it no longer infers a read failure from 0x0440 == 0xFF:

  • The corresponding valid_mask bit is 1 → the field is the real register value (it can be 0)
  • The corresponding bit is 0 → that register read failed this time and the field returns None (it is not "really read 0")

The status key in the dictionary comes from bit0 of ESC register 0x0440: 0 = the watchdog has overflowed / expired, 1 = the watchdog is normal or not enabled; bits other than bit0 are reserved. 0x0442 / 0x0443 are watchdog overflow counters (write 0 to reset, reading does not clear them) and are not the same thing as the status bit in 0x0440.

Returns:

  • Optional[dict] — watchdog status dictionary with the following keys:
    • status (int | None) — watchdog status value (0x0440 bit0: 0 = overflowed/expired, 1 = normal or not enabled); None on a read failure
    • counter (int | None) — watchdog counter 0x0442 (accumulated expiration count); None on a read failure
    • divider (int | None) — current divider value 0x0400; None on a read failure
    • pd_timeout (int | None) — current process data watchdog timeout value 0x0420; None on a read failure
    • counter_pdi (int | None) — PDI watchdog overflow counter 0x0443; None on a read failure
    • valid_mask (int) — the valid bit set of this read (status=0x0001 / counter=0x0002 / divider=0x0004 / time_pd=0x0008 / counter_pdi=0x0010)

Example:

status = slave.watchdog_status
if status is None:
print("看门狗状态读取失败") # Failed to read watchdog status
elif status['status'] is None:
print("0x0440 本次未读到(未知),不按健康处理") # 0x0440 was not read this time (unknown); not treated as healthy
elif (status['status'] & 0x01) == 0:
print(f"看门狗触发! 计数={status['counter']}") # Watchdog triggered! Count={status['counter']}
else:
print(f"看门狗正常, valid_mask=0x{status['valid_mask']:04X}") # Watchdog OK, valid_mask=0x{status['valid_mask']:04X}

State transitions​

set_state(state, timeout_ms=5000)​

def set_state(state: EcState, timeout_ms: int = 5000) -> bool

Set the EtherCAT state of a single slave (with a timeout). Use this for manual recovery or to move one slave to a specified state; for a network-wide state machine use master.set_state().

Parameters:

  • state (EcState) — target state
  • timeout_ms (int) — timeout in milliseconds, default 5000

Returns:

  • bool — whether the call succeeded
note

State transitions follow the EtherCAT standard state machine flow, and the protocol layer handles intermediate states automatically. For example, switching from INIT to OP passes through PreOp → SafeOp → OP automatically.

Example:

# Manually recover a single slave to OP
if slave.state != EcState.OP:
slave.set_state(EcState.OP)

# Switch the slave to Init (reset)
slave.set_state(EcState.INIT, timeout_ms=5000)

Hot-plug and reconfiguration​

When a slave has been powered off and plugged back in or replaced and then re-enters PreOp, the underlying layer sets needs_reconfig to indicate that the startup parameters and configuration of that slave need to be replayed:

  • needs_reconfig — read-only flag, True = configuration is waiting to be replayed, False = nothing to replay
  • clear_reconfig_flag() — clear the flag manually

When the flag is True, the PreOp reconfiguration callback registered by the SDK automatically replays the startup parameters of the IP / PS / SO transitions at both the Before / After timings, then clears the flag. You only need to clear it manually when you have completed the reconfiguration yourself and do not want the SDK to replay it again.

clear_reconfig_flag()​

def clear_reconfig_flag(self)

Clear the reconfiguration flag of this slave. It returns no value.

Once the flag is cleared, the next PreOp reconfiguration callback no longer replays startup parameters automatically for this slave.

Example:

if slave.needs_reconfig:
slave.apply_startup_params() # replay itself (default IP + After)
slave.clear_reconfig_flag()

Real-time status queries​

slave.state / slave.error_code are adaptive read sources: during stable OP operation they read the cache maintained by the cycle health check (zero frames); when not in OP (INIT / PreOp / SafeOp / hot-plug) or when the cache is not filled, they first refresh in real time once before returning, so you cannot treat them as "pure cache values that are always zero-frame". When you need a forced live read for "right now", use the properties below (they really send one frame and compete for the port lock; read them only when confirming a state transition or locating a fault):

PropertyReturnsDescription
state_live_readLiveReadLive state read + four-state trust; value is the raw AL Status byte (including the bit4 Error bit)
state_liveOptional[EcState]Gives a value only when VALID, otherwise None; None != EcState.NONE
state_raw_liveOptional[int]Live raw byte; None when untrusted
al_status_code_live_readLiveReadLive AL code (lossless 16-bit) + four-state trust
al_status_code_liveOptional[EcALState]Gives a value only when VALID, otherwise None (not NO_ERROR)
al_status_code_raw_liveOptional[int]Live lossless raw code; None when untrusted

LiveRead and the four trust states​

Only a value that passes is_valid (that is, validity == VALID) may be used as the current value; the other three states must never be taken as "this is how it is right now".

ValueMeaningUsable as the current value
UNKNOWN(0)No usable read (call failed / old library missing the entry point / invalid handle)No. Unknown != normal
VALID(1)This measurement produced a result usable as the current valueYes
STALE(2)A value was obtained, but it is confirmed not current (the lower layer uses 0 as a placeholder when the slave is lost / not responding)No, this is a residual value
DEGRADED(3)A value was obtained, but only partial evidence is available (liveness state / probe unreadable or unknown)Not as confirmation

Live state criterion: 0 / 0xFF / low 4 bits are 0 -> UNKNOWN; otherwise -> VALID.

Live AL code criteria:

VerdictTriggervalue
UNKNOWNThe call failed, or it returned 0xFFFF (the unavailable sentinel)0xFFFF
DEGRADEDThe liveness state / probe read failedRaw code
STALEis_lost is true, or the probe confirms no responseRaw code (residual)
DEGRADEDProbe evidence is insufficient (unknown)Raw code
VALIDis_lost is False and the probe confirms the slave is onlineRaw code
A lost slave is not "no error"

The lower layer returns 0 for a lost / non-responding slave; that 0 is the "no data" placeholder, not "no error". al_status_code_live_read uses the liveness state and probe evidence to file it as STALE; the convenience entry points give None in that case. Never read 0 / None as "the device confirmed no fault".

The view semantics of slave.state and slave.error_code must be kept clear: state gives only the base state (it drops the Error bit), while error_code / al_status_code are enum views (codes outside the table carry the original code); for a lossless integer use state_raw / al_status_code_raw, and for a "readable state with the Error bit" use slave.status.format(). On a read failure state_raw / al_status_code_raw return the 0 / 0xFFFF sentinels respectively — do not treat them as the device's real value.

The AL mirror (diagnostics.al_status_mirror) holds only the low 8 bits of the code, so codes ≥ 0x0100 are truncated; for the complete 16-bit code use al_status_code_raw or al_status_code_live_read.

ESC register access (advanced)​

Read and write slave ESC (EtherCAT Slave Controller) registers directly, for fault diagnostics, custom ESC operations and register-level debugging. General register reads and writes do not automatically fall back to the secondary NIC port or broadcast (that capability exists only in write_dl_port()).

Advanced API

You do not need to call this during normal SDK use — state transitions / PDO / mailbox flows configure the registers automatically. This API is for in-depth diagnostics and special scenarios (for example reading error counters, forcing a port policy, or debugging when an ESI burn-in does not take effect).

Register definitions are in ETG.1000.4 §6 / ETG.1000.6 §5 (public standards), for example:

RegisterDescription
0x0000Type / Revision / Build (device type)
0x0030AL Control (master initiates a state request)
0x0130AL Status (current slave state)
0x0134AL Status Code (error code)
0x0300-0x0313Port 0-3 error counters (RX Error / Invalid Frame / Lost Link)
0x0400-0x043FWatchdog configuration (divider / PDI timeout / PD timeout)
0x0440-0x0443SM watchdog status / overflow counters: 0x0440 bit0 (0 = overflowed/expired, 1 = normal or not enabled; 0xFF = read failure/unknown); 0x0442/0x0443 reset on write 0, reading does not clear

read_register(addr, length)​

def read_register(self, addr: int, length: int) -> Optional[bytes]

Read a slave ESC register (FPRD).

Parameters:

  • addr (int) — register address (for example 0x0130 = AL Status)
  • length (int) — number of bytes to read (1 / 2 / 4 and so on)

Returns:

  • Optional[bytes] — returns the byte data on success; returns None on failure (slave offline / timeout)

write_register(addr, data)​

def write_register(self, addr: int, data: bytes) -> bool

Write a slave ESC register (FPWR).

Parameters:

  • addr (int) — register address
  • data (bytes) — data to write

Returns:

  • bool — returns True on success

Example:

slave = master[1]                 # 1-based index, the 1st slave

# Read AL Status (0x0130, 2 bytes)
data = slave.read_register(0x0130, 2)
if data:
state = int.from_bytes(data, 'little')
print(f"AL Status = 0x{state:04X} (state={state & 0x0F}, err={(state & 0x10) != 0})")

# Read AL Status Code (0x0134, error code)
code_bytes = slave.read_register(0x0134, 2)
if code_bytes:
code = int.from_bytes(code_bytes, 'little')
print(f"AL Status Code = 0x{code:04X}")

# Write AL Control = 0x04 (request SafeOp)
slave.write_register(0x0030, bytes([0x04, 0x00]))

EEPROM (SII) access​

Read and write the slave SII EEPROM (Slave Information Interface, ETG.1000.6 §6). The EEPROM stores device identity and configuration information such as vendor_id / product_code / revision_no / serial_no / SyncManager / FMMU / PDO mapping / Strings. The SDK already reads it automatically at configuration time, so applications generally do not need direct access.

Dangerous operation

Use EEPROM writes with care — a wrong write can corrupt the slave identity information and, in the worst case, permanently brick the slave, requiring the vendor's tool to recover. Use it only in the following scenarios:

  • Burning an alias address (ESC 0x0012)
  • Repairing factory data that was overwritten by mistake
  • Vendor-authorized firmware / parameter burning

EEPROM writes require the slave to be in Init / PreOp state; writes are rejected in OP state.

EEPROM size is usually 1 KB - 16 KB (word-addressed, 1 word = 2 byte). The first 8 words hold basic vendor information, followed by the category linked list (Strings / General / FMMU / SyncM / TxPdo / RxPdo / DC / End=0xFFFF).

read_eeprom(byte_offset, byte_length)​

def read_eeprom(self, byte_offset: int, byte_length: int) -> bytes

Read a byte region of the slave SII EEPROM (looping by word). The SDK handles BUSY polling and word alignment automatically; applications should prefer this high-level API.

Parameters:

  • byte_offset (int) — starting byte offset (an odd offset is aligned down to the word boundary and the corresponding byte is taken)
  • byte_length (int) — number of bytes to read (an even value is recommended; for an odd value the low byte is taken at the end)

Returns:

  • bytes — byte_length bytes of data; returns empty b"" on failure or invalid arguments

write_eeprom(byte_offset, data)​

def write_eeprom(self, byte_offset: int, data: bytes) -> bool

Write a byte region of the slave SII EEPROM (looping by word). Both byte_offset and len(data) must be even.

Parameters:

  • byte_offset (int) — starting byte offset (must be even)
  • data (bytes) — bytes to write (the length must be even)

Returns:

  • bool — returns True when every word was written successfully

Example:

slave = master[1]                 # 1-based index, the 1st slave

# Read vendor_id (EEPROM byte offset 0x10, length 4)
data = slave.read_eeprom(0x10, 4)
if len(data) == 4:
vendor_id = int.from_bytes(data, 'little')
print(f"VendorID = 0x{vendor_id:08X}")

# Read the first 16 header bytes (including PDIControl / StationAlias and so on)
header = slave.read_eeprom(0, 16)
print(f"EEPROM 头部: {header.hex()}") # EEPROM header: {header.hex()}

# Write the alias section (consecutive words starting at EEPROM byte offset 0x08)
# The slave must be in Init/PreOp state
if slave.state == EcState.INIT:
ok = all([
slave.write_eeprom(0x08, bytes([0x01, 0x00])), # alias = 1 (word 0x04)
slave.write_eeprom(0x0A, bytes([0x00, 0x00])), # Reserved field (word 0x05)
])

For byte-range access use read_eeprom / write_eeprom; for category-level access use slave.sii (below). For identity and similar values, see the wrapped properties in the property table above.

slave.sii — tri-state category reads​

slave.sii (SiiAccessor) is the Category-level SII entry point: it locates / reads any category through the ETG.1000.6 category chain and parses the General Category into a struct. read_eeprom / write_eeprom are byte-range access; the two complement each other.

class SiiReadStatus(IntEnum):
OK = 0 # Read succeeded
NOT_FOUND = 1 # The chain is readable and really has no such category (a normal result, not an error)
READ_FAILED = 2 # SII cannot be read; must not be treated as "does not exist"

class SiiReadResult(NamedTuple):
status: SiiReadStatus
value: Optional[object] # A real value only when OK

def try_find_category(self, cat: int) -> SiiReadResult
def try_read_category(self, cat: int, max_bytes: int = 4096) -> SiiReadResult
def try_get_general_info(self) -> SiiReadResult
def try_read_identity(self) -> SiiReadResult # value = SiiIdentityInfo
def try_read_serial_number(self) -> SiiReadResult # value = int

Shape of value when OK:

  • try_find_category → (byte_offset, byte_size)
  • try_read_category → bytes (length 0 is a valid empty segment and returns b"")
  • try_get_general_info → SiiGeneralInfo
  • try_read_identity → SiiIdentityInfo
  • try_read_serial_number → int (the true 32-bit serial number, possibly 0)

Attribution rules (the tri-state, aligned case by case):

  • SIIEnumerateCategories returns a negative value (even the SII context cannot be obtained) → READ_FAILED
  • The category is present on the chain but locating it failed → READ_FAILED (being on the chain means it does not "not exist")
  • The category chain is readable and does not contain the category → NOT_FOUND (a normal result)
  • Locating succeeded → OK
  • try_read_category: locate first (same attribution), return that status directly when it is not OK; if locating succeeded but the data cannot be read → READ_FAILED (no partial data)
  • try_get_general_info: on a failed read, if try_find_category(30) is NOT_FOUND → NOT_FOUND, otherwise READ_FAILED
Difference from the old Optional entries

find_category() / read_category() / get_general_info() use None to mean both "really does not exist" and "read failed"; the two are the same shape in the old signatures. Use the tri-state try_* entries to tell them apart; the old entries keep their return shape and behavior.

Example:

from darra_ethercat.slave.core import SiiReadStatus

sii = slave.sii

r = sii.try_find_category(30) # General Category
if r.status is SiiReadStatus.OK:
offset, size = r.value
print(f"General @0x{offset:X} ({size} 字节)") # General @0x{offset:X} ({size} bytes)
elif r.status is SiiReadStatus.NOT_FOUND:
print("该从站没有 General 分类") # This slave has no General category
else:
print("SII 读不出来(不是'不存在')") # SII could not be read (this is not the same as 'not present')

data = sii.try_read_category(10) # Strings Category
if data.status is SiiReadStatus.OK:
print(f"Strings 共 {len(data.value)} 字节") # Strings total {len(data.value)} bytes

info = sii.try_get_general_info()
if info.status is SiiReadStatus.OK:
print(f"设备名索引={info.value.name_idx}") # Device name index={info.value.name_idx}

SII identity area and true serial number​

The identity area is a fixed ESC area (ETG.1000.6: word 0x0008..0x000F) and does not go through the category chain, so try_read_identity / try_read_serial_number only ever produce OK / READ_FAILED and never NOT_FOUND.

wordFieldDescription
0x0008 / 0x0009vendor_idV (Vendor ID)
0x000A / 0x000Bproduct_codeP (Product Code)
0x000C / 0x000Drevision_noR (Revision No)
0x000E / 0x000Fserial_noSerial (serial number)

Each item is assembled into 32 bits with the low word first (low | high << 16), matching the EEPROM direct-read convention.

from darra_ethercat.slave.core import SiiReadStatus

ident = slave.sii.try_read_identity()
if ident.status is SiiReadStatus.OK:
i = ident.value
print(f"V=0x{i.vendor_id:08X} P=0x{i.product_code:08X} "
f"R=0x{i.revision_no:08X} Serial={i.serial_no}")

serial = slave.sii.try_read_serial_number()
if serial.status is SiiReadStatus.OK:
print(f"序列号真值 = {serial.value}") # May be 0: the real value is 0

A failed read is never folded to 0: if any of the 8 identity words cannot be read the result is READ_FAILED (value is None). An incomplete identity area means no partial data is delivered, and it is not passed off as "the device wrote no identity". READ_FAILED and "the real value is 0" are two different things and callers must handle them separately.

The three meanings of serial number 0​

slave.serial_number is a native runtime identity snapshot, and 0 can mean any of three things:

CaseMeaningCorrect way to read it
Not readCold configuration only reads the SER word for slaves that miss the ESI; slaves that hit the ESI keep 0slave.try_get_serial_number()
Real value 0The serial number declared in the device's SII really is 0slave.try_get_serial_number() returns 0 (not None)
Read failedThe SII cannot be readslave.try_get_serial_number() returns None

slave.try_get_serial_number() -> Optional[int] order: (a) the native snapshot is non-0 → return it directly without touching the EEPROM; (b) the snapshot is 0 → read SII word 0x000E..0x000F live.

  • Returns int = the real value (possibly 0)
  • Returns None = cannot be read (not equal to 0 — unknown is never folded to 0)
  • While the snapshot is 0, every call really reads the EEPROM; callers that need it frequently should cache it themselves
sn = slave.try_get_serial_number()
if sn is None:
... # Cannot be read — unknown; do not treat it as serial 0
else:
print(f"序列号 = {sn}") # sn may be 0; that is the value the device declares

DL Port control​

Read and write the ESC DL Port Control register (0x0101) directly, for port fault injection tests and manual diagnostics of redundancy / ring topologies.

Advanced API

You do not need to call this during normal operation. Most users should diagnose port state by subscribing to the slave_port_link_changed event and reading the port error counters. Use it only when you need to actively simulate a port fault (testing redundancy switching) or investigate a specific port problem.

The ESC has 4 physical ports P0 / P1 / P2 / P3; the bit definitions of the DL Port Control register are as follows:

DLPORT valueBehavior
0x00Auto — all ports managed automatically by the ESC (default)
0x03Close P0
0x0CClose P1
0x30Close P2
0xC0Close P3

Only write_dl_port() automatically switches to the secondary NIC port / broadcast write-back when a port is unavailable: after P0 is closed it can still write back. write_register / read_register have no fallback; after P0 is closed, access through them does not automatically switch to the secondary port or broadcast.

Two access paths
  • The dedicated slave.write_dl_port(value) / slave.read_dl_port() methods: writes have a three-level fallback (primary → secondary → broadcast APWR); reads go through the primary port only and have no secondary fallback; on failure they return False / None respectively.
  • The general register read/write write_register(addr, data) / read_register(addr, length) hit 0x0101 directly: the register location is the same, but they send a single frame with no fallback, so they are not equivalent to the dedicated methods. When P0 is normal both produce the same result; after P0 is closed, write_dl_port may still succeed while write_register fails (neither path has a fallback on the read side).
Export scope of the dedicated methods

write_dl_port() / read_dl_port() are for debugging / port fault injection. When the runtime library does not export the corresponding debug symbol, they return False / None respectively (no exception), so do not read that as "the register write definitely failed". For production code that needs to read or write 0x0101, use write_register(0x0101, ...) / read_register(0x0101, 1); the cost is losing the write fallback of write_dl_port (the read side never had a fallback).

Write the DL Port Control register (0x0101):

# See the table above for value (0-255)
ok = slave.write_dl_port(value) # Dedicated method with port fallback
ok = slave.write_register(0x0101, bytes([value])) # General register write, single frame, no fallback

Read the current DL Port Control register value:

dlport = slave.read_dl_port()                # Dedicated method; returns None on a read failure
data = slave.read_register(0x0101, 1) # General register read, single frame, no fallback
dlport = data[0] if data else 0

Example:

# Simulate a P1 port fault (test redundancy switching)
ok = slave.write_register(0x0101, bytes([0x0C]))
print(f"关闭 P1: {'成功' if ok else '失败'}") # Closing P1: {'success' if ok else 'failure'}

# Read back to confirm
data = slave.read_register(0x0101, 1)
dlport = data[0] if data else 0
print(f"当前 DLPORT = 0x{dlport:02X}") # Current DLPORT = 0x{dlport:02X}

# Restore after the fault is cleared
slave.write_register(0x0101, bytes([0x00])) # Restore Auto
Use with redundancy diagnostics

After closing a port, watch master.events.add_slave_port_link_changed() and master.diagnostics_info.break_point to verify that redundancy switching takes effect.

Startup configuration​

The "whether to write PDO Assignment / PDO Configuration" and "whether Complete Access is supported" settings of the Startup configuration are fields in the ENI/DENI configuration file and are not exposed as slave object properties. The Startup interface on the slave object only has the startup parameter list.

Automatic startup (ENI/DENI and MDP)​

Startup fields declared in the ENI/DENI configuration file take effect when the configuration is loaded and do not need to be sent slave by slave; modular devices (MDP) and SM physical parameters are orchestrated automatically by the master — call master.enable_auto_startup() during chained initialization, and it executes at build().

Configuration source declaration (StartupAutoConfig)​

The declaration interface on darra_ethercat.slave.startup.StartupAutoConfig (not on the slave object): it only records the declaration "the configuration came from ENI or DENI" and is not responsible for loading files — loading ENI / DENI still goes through their respective configuration loading entry points. The class is defined in the darra_ethercat.slave.startup module, and ConfigSource is exported by both the package root and darra_ethercat.data.

class ConfigSource(IntEnum):
UNKNOWN = 0 # Undeclared (instance default; must not be written explicitly)
ENI = 1 # Configuration came from ENI (standard ETG.2100 network configuration XML)
DENI = 2 # Configuration came from DENI (Darra extended network configuration, an ENI superset)

class StartupAutoConfig:
def set_config_source(self, source) -> None
def set_config_source_eni(self) -> None # Equivalent to set_config_source(ConfigSource.ENI)
def set_config_source_deni(self) -> None # Equivalent to set_config_source(ConfigSource.DENI)

@property
def config_source(self) -> str
@property
def has_executed(self) -> bool
CategoryPropertyTypeRead/writeDescription
Configuration sourceset_config_source(source)Nonewrite-onlyDeclares the configuration source; accepts ConfigSource.ENI / ConfigSource.DENI as well as the equivalent strings "ENI" / "DENI"; UNKNOWN, out-of-range values and unrecognized strings raise ValueError
set_config_source_eni()Nonewrite-onlyForwarder to set_config_source(ConfigSource.ENI), kept for compatibility
set_config_source_deni()Nonewrite-onlyForwarder to set_config_source(ConfigSource.DENI), kept for compatibility
config_sourcestrread-onlyReads back the declared source: "ENI" / "DENI"; an empty string "" when nothing has been declared (still returns str, no enum read-back)
Execution statushas_executedboolread-onlyWhether automatic configuration has been executed; default False

Write and read-back:

  • set_config_source(ConfigSource.ENI) → config_source reads back "ENI" and sets has_executed to True at the same time
  • set_config_source(ConfigSource.DENI) → config_source reads back "DENI" and likewise sets has_executed = True
  • May be called repeatedly: a later declaration overwrites the previous one (ENI ↔ DENI switching is supported) and is read back through config_source
  • ConfigSource.UNKNOWN, out-of-range values and unrecognized strings all raise ValueError — "undeclared" is the instance default, and writing it explicitly would be fabricating a source
  • Defaults: after creating a new instance, config_source is "" and has_executed is False
  • They only change the declaration field on this instance; they do not load files, read the slave or write to the slave, and issue no bus operation
from darra_ethercat import ConfigSource

# auto = the StartupAutoConfig instance you hold
auto.set_config_source(ConfigSource.DENI)
print(auto.config_source) # "DENI"
print(auto.has_executed) # True — declaring a source sets the flag as well

auto.set_config_source("ENI") # The equivalent string is accepted too
print(auto.config_source) # "ENI"
This is SDK-side declaration state, not a native read-back

native does not record the ENI / DENI source per slave — it only records two things per slave: "explicitly planned (explicit_replace)" and "merged ESI defaults (esi_installed)". config_source is the declaration value kept on the SDK side: it reads back whatever the caller declared. Actually loading configuration still goes through the master's set_eni / load_config_* path.

has_executed is a declaration, not a read-back

has_executed only means "has been declared as having executed automatic configuration"; it is not a read-back of the slave's actual running state. Declaring a source sets it to True at the same time so upper layers can tell whether the configuration is already in place (the SDK has no auto-startup executor today; whether to skip is the caller's decision). Startup fields declared in the ENI/DENI still take effect when the configuration is loaded (see the previous section), and this interface does not change the loading behavior.

Managing startup parameters manually (slave.startup)​

StartupParameterList methods (accessed through slave.startup):

  • add(index, sub_index, data, transition=StartupTransition.IP, priority=0, write_timing=None, complete_access=False, description="") — creates and adds a startup parameter from explicit fields, returns the created StartupParameter
  • add_parameter(param) — adds an already created StartupParameter object
  • remove(param) — removes the specified StartupParameter object, returns bool
  • clear() — clears all startup parameters, returns a result code (int)
  • apply_all(slave) — applies all startup parameters to the slave, returns the number successfully applied (int)
Note the difference between add and add_parameter

add() takes explicit fields and constructs a StartupParameter; add_parameter() takes an already constructed StartupParameter object.

Example:

from darra_ethercat import StartupParameter
from darra_ethercat.data.types import StartupTransition

# First approach: add() with explicit arguments
slave.startup.add(
index=0x1C12,
sub_index=0,
data=bytes([0]),
transition=StartupTransition.PS,
priority=10,
)

# Second approach: construct a StartupParameter object first, then call add_parameter()
param = StartupParameter(
index=0x1C13,
sub_index=0,
data=bytes([0]),
transition=StartupTransition.PS,
priority=10,
)
slave.startup.add_parameter(param)

Related structures:

  • IP — Init → PreOp, default AfterTransition
  • PS — PreOp → SafeOp, default BeforeTransition
  • SO — SafeOp → Op, default BeforeTransition
  • OS — Op → SafeOp, default AfterTransition
  • SP — SafeOp → PreOp, default AfterTransition
  • PI — PreOp → Init, default BeforeTransition

startup_param_count​

@property
def startup_param_count(self) -> int

Number of startup parameters registered for this slave.

Returns:

  • int — number of registered startup parameters; when the master / slave index is invalid or the slave is not initialized it returns a negative error code (never folded into 0)

Example:

count = slave.startup_param_count
if count < 0:
print("启动参数数量读取失败") # Failed to read the startup parameter count
else:
print(f"已登记 {count} 条启动参数") # {count} startup parameters registered

apply_startup_params(transition=TRANS_IP, timing=TIMING_AFTER)​

def apply_startup_params(self, transition: int = TRANS_IP,
timing: int = TIMING_AFTER) -> int

Send the startup parameters registered for this slave to the slave, selected by state transition phase and write timing.

Parameters:

  • transition (int) — state transition phase: TRANS_IP=0 (Init→PreOp) / TRANS_PS=1 / TRANS_SO=2 / TRANS_OS=3 / TRANS_SP=4 / TRANS_PI=5, default TRANS_IP
  • timing (int) — write timing: TIMING_BEFORE=0 / TIMING_AFTER=1, default TIMING_AFTER

Returns:

  • int — number of startup parameters successfully applied this time
  • 0 — nothing was applied for the current sample (this phase has no parameters waiting to be sent, or this call was deferred; it does not mean the phase is complete)
  • A negative number — failure error code (invalid master / slave index, not initialized, SDO write failure and so on); a failure is never folded into 0

Notes:

  • Only entries whose registered phase and timing match are sent.
  • Normal state transitions apply startup parameters automatically through the master; call this directly only when you manage startup parameters manually.

Example:

from darra_ethercat import TRANS_PS, TIMING_BEFORE

applied = slave.apply_startup_params(TRANS_PS, TIMING_BEFORE)
if applied < 0:
print(f"启动参数下发失败, 错误码 {applied}") # Failed to send the startup parameters, error code {applied}
else:
print(f"本次应用 {applied} 条") # {applied} applied this time

clear_startup_params()​

def clear_startup_params(self) -> int

Clear all startup parameters registered for this slave.

Returns:

  • int — 0 = success; a negative number = error code (invalid master / slave index, not initialized)

Notes:

  • An empty queue after clearing still counts as a complete replacement, and startup parameters are not filled back in automatically from the ESI afterwards.
  • Only the registration table is cleared; parameter values already written to the slave are not withdrawn. To restore the slave, send them again or restart the slave.

Example:

rc = slave.clear_startup_params()
if rc == 0:
print("启动参数已清空") # Startup parameters cleared

Identity verification and domain information​

The slave's domain information is read through public properties: the identity returns a dictionary and the rest are ordinary Python values.

Reading and verifying identity​

identity = slave.identity
# {'vendor_id': 0x00000002, 'product_code': 0x0000000A,
# 'revision_no': 0x00010000, 'serial_no': 0x00001234}

from darra_ethercat import SlaveIdentity

expected = SlaveIdentity(
vendor_id=0x00000002,
product_code=0x0000000A,
revision_no=0x00010000,
serial_no=0x00001234,
)
ok = slave.verify_identity(expected, check_revision=True, check_serial=False)
  • slave.identity returns None on a read failure (slave offline / not ready); do not treat that as an all-0 identity.
  • verify_identity checks the revision number by default and not the serial number; with check_serial=True the serial number is also compared.

Common domain properties​

CategoryPublic propertyTypeRead/writeDescription
Groupsslave.groupintread/writeGroup the slave belongs to; a failed write throws RuntimeError
Optionalityslave.optionalboolread/writeWhether the slave is optional (is_optional is the equivalent entry point)
Device informationslave.namestrread-onlySlave group name (EEPROM group_name, the ESI GroupType name)
Topologyslave.active_portsintread-onlyActive port bitmap
slave.parent_indexintread-onlyParent slave index
slave.parent_stationintread-onlyParent slave index (historical name; it is actually the index, 0 = master)
DCslave.propagation_delayintread-onlyPropagation delay (ns)
slave.dc_activeintread-onlyAssignActivate value, 0 = disabled
Mailboxslave.mbx_protointread-onlySupported mailbox protocol bitmap
slave.mbx_countintread-onlyMailbox link-layer protocol counter

Each mailbox protocol's is_supported (such as coe.is_supported) combines the slave.mbx_proto protocol bits (positive evidence) with the SII General details (negative authority); protocols without a negative authority field only return True / None and are never folded into False.