FoE — file transfer
FoE (File over EtherCAT) uploads files to and downloads files from a slave.
Feature overview
| Capability | Description |
|---|---|
| Upload / download | File-level PUT / GET; a progress bar shows the transfer status in real time |
| Cancel button | Abort the current FoE operation mid-transfer so it does not keep the slave occupied |
| Default timeout | Configure the default FoE operation timeout on the FoE tab; all transfers share it |
| Default password | Cache frequently used vendor passwords (such as a firmware unlock password) so you do not type them every time |
| BUSY progress callback | When the slave returns BUSY, the progress bar extends and shows a waiting state instead of reporting failure |
| Error code explanation | On a failed transfer, resolves the error code per ETG.1000.6 Table 92 and shows a Chinese explanation |
Typical use: firmware updates, flexible configuration switching, log export, parameter backup/restore.
Generated code: tick FoE file operations in the export window to generate a file transfer example in the code.
Quick start
- Put the slave into the BOOT or PRE_OP state (firmware updates usually need BOOT)
- Open the FoE tab in the configuration tool
- Enter the unlock password supplied by the vendor in the Default password field (if required)
- Adjust the Default timeout field for the file size (10 seconds for an ordinary file, 60~120 seconds for a large firmware image)
- Select a local file and click Upload to write it to the slave; or enter a file name and click Download to read it from the slave
- Watch the progress bar; click Cancel to abort the transfer if needed
Cancelling a transfer
A large firmware file can take tens of seconds in a single transfer, so the FoE tab provides a Cancel button:
- The Cancel button becomes available as soon as the transfer starts
- Clicking it sends an abort request to the slave immediately; the progress bar stops at the current percentage
- Once the cancel completes, the slave is back in BOOT/PRE_OP and you can retry immediately
Default timeout
Configure the default timeout in the settings area at the top of the FoE tab:
- Ordinary files — 10 seconds is recommended
- Large firmware files — 60~120 seconds is recommended
- Once set, all FoE operations share it; there is no need to set it per transfer
Default password
Some vendors require a password on FoE writes (to prevent accidental firmware flashing). The FoE tab provides a Default password field:
- Enter it once and it is saved in the project file, then filled in automatically next time
- It is attached to uploads and downloads by default; a checkbox lets you omit it for one transfer
- Stored locally only; it is not uploaded to the cloud
BUSY progress display
While the slave erases or writes Flash it replies FoE BUSY together with an estimated remaining time:
- The progress bar switches to a waiting style (flowing horizontally) and keeps the current percentage
- The status bar shows
BUSY: 从站正在擦写, 约剩 N 秒 - This is not mistaken for a timeout failure
Error code explanation table
On a failed transfer, a dialog resolves the error code per ETG.1000.6 Table 92:
- 0x8000 NotDefined — undefined error
- 0x8001 NotFound — file not found
- 0x8002 AccessDenied — access denied (permission or password error)
- 0x8003 DiskFull — not enough storage space on the slave
- 0x8004 Illegal — illegal operation (file name or path not allowed)
- 0x8005 PacketNumberWrong — wrong packet number (retry is recommended)
- 0x8006 AlreadyExists — the file already exists (overwriting is not allowed)
- 0x8007 NoUser — the current user does not exist
- 0x8008 BootstrapOnly — this operation is allowed only in the BOOT state
- 0x8009 NotInBootstrap — the slave is not in the BOOT state
- 0x800A NoRights — no file operation rights (wrong password)
- 0x800B ProgramError — internal programming error in the slave