SoE - servo drive profile
What is SoE?
SoE (Servo Drive Profile over EtherCAT) is a high-performance motion control protocol based on the IEC 61800-7-204 (SERCOS III) standard.
SoE versus CoE
| Characteristic | SoE | CoE (CiA 402) |
|---|---|---|
| Origin | SERCOS III motion control standard | CANopen general standard |
| Parameter addressing | IDN (16-bit identifier) | Index + subindex |
| Main application | Servo drives, CNC systems | General-purpose servos, automation equipment |
Core concepts
IDN (Identification Number)
SoE identifies parameters by IDN rather than by object dictionary index:
- S-x-xxxx — standard SERCOS IDN (for example S-0-0134)
- P-x-xxxx — product-specific IDN (for example P-0-1000)
IDN structure:
- S/P: standard / product-specific (the highest bit of the 16-bit IDN)
- Middle digit: parameter set (0 = standard parameter set, 1-7 = product/vendor parameter set)
- Last 4 decimal digits: parameter number (the low 12 bits of the 16-bit IDN)
For example, the 16-bit IDN of S-0-0051 is 0x0033, and for S-0-0047 it is 0x002F.
Common standard IDNs
Control and status
| IDN | Name | Type | Description |
|---|---|---|---|
| S-0-0134 | Master Control Word | UINT16 | Master control word (start, stop and so on) |
| S-0-0135 | Drive Status Word | UINT16 | Drive status word (running, fault and so on) |
| S-0-0142 | Control Unit Cycle Time | UINT32 | Control cycle time |
| S-0-0143 | Drive Cycle Time | UINT32 | Drive cycle time |
Position control
| IDN | Name | Type | Description |
|---|---|---|---|
| S-0-0047 | Position Command Value | INT32 | Position command value |
| S-0-0051 | Position Feedback Value | INT32 | Position feedback value (for the second feedback of a dual-encoder device, use the IDN given in the device manual) |
Velocity and torque
| IDN | Name | Type | Description |
|---|---|---|---|
| S-0-0036 | Velocity Command Value | INT32 | Velocity command value |
| S-0-0040 | Velocity Feedback Value | INT32 | Velocity feedback value |
| S-0-0084 | Torque Command Value | INT16 | Torque command value |
| S-0-0085 | Torque Feedback Value | INT16 | Actual torque feedback |
Diagnostics and status
| IDN | Name | Type | Description |
|---|---|---|---|
| S-0-0095 | Diagnostic Message | STRING | Current diagnostic message |
| S-0-0011 | Class 1 Diagnostic | UINT16 | first-level diagnostic code |
| S-0-0012 | Class 2 Diagnostic | UINT16 | second-level diagnostic code |
SoE communication services
Cyclic data (process data / SoE PDO)
Used for cyclic data exchange (position, velocity, torque and so on):
- Through the PDO mapping
- Updated every control cycle
- Very low latency
Acyclic communication (service channel / acyclic telegram)
Used for parameter read and write, configuration and diagnostics:
- Transferred through the mailbox
- Supports read, write and command execution
- Used for start-up, configuration and monitoring
SoE service types
| Service | Code | Description |
|---|---|---|
| Read Request | 0x01 | Read IDN data, to obtain status and parameters |
| Read Response | 0x02 | Read response, returns the data |
| Write Request | 0x03 | Write IDN data, to modify parameters |
| Write Response | 0x04 | Write response, confirms the write |
| Notification | 0x05 | The slave reports spontaneously (parameter change notification) |
| Emergency | 0x06 | Emergency notification, fault alarm |
The service code is the low 3 bits of the first byte of the SoE header (byte0 & 0x07); it is not a coding where "request and response each occupy a section" — the response codes are independent values, and high-bit markers such as 0x81 / 0x82 do not exist.
SoE drive state machine
SoE defines standard drive state transitions:
| State | Description | Characteristic |
|---|---|---|
| S0 - not ready | Initialisation state | The drive is powered up |
| S1 - standby | Parameters ready | Parameters can be configured |
| S2 - ready to run | Communication synchronised | Waiting for enable |
| S3 - running | Motor enabled and running | Accepts motion commands |
| S4 - fault | Error state | Fault recovery required |
SoE vs CoE - how to choose
If a device supports both SoE and CoE, SoE is recommended — SoE uses standardised IDN numbering, parameter access is simpler and more direct, and it is fully compatible with SERCOS III. CoE offers a more flexible object dictionary structure and suits scenarios that need complex configuration.
Technical advantages
Highly standardised
The SERCOS association defines strictly:
- Parameter naming and numbering
- State machine transition logic
- Data types and units
- Error code definitions
SoE drives from different vendors are highly consistent.
Real-time capability
- There is no product-imposed lower limit on the cycle (the configured value is applied as given, with no silent clamping); the cycle actually achievable depends on the CPU, the isolation configuration, the NIC and the slaves, and is measured on site
- Deterministic communication latency
- Hardware timestamps
- Distributed Clocks (DC) synchronisation
Complete functionality
Built-in motion control functions:
- Position, velocity and torque control modes
- Electronic gear and cam
- Limit and safety functions
- Interpolation and trajectory planning
Strong diagnostics
- Hierarchical diagnostic system
SoE support in the Darra SDK
The Darra SDK provides full SoE protocol support:
Features
| Function | Description |
|---|---|
| IDN read and write | Supports all standard and product-specific IDNs |
| Cyclic data | Maps the SoE PDO automatically |
| State machine management | Automatic drive state transitions |
| Diagnostic parsing | Parses SERCOS diagnostic messages |
| Multi-axis synchronisation | Supports multi-axis time-synchronised control |
Device detection
The SDK detects SoE devices automatically and loads the matching configuration.
Summary